PULSE 6 SERVICE MANUAL
PAGE 7.5
SEPT 2011SUNRISE MEDICAL
Section 7
6. Use 17 mm Rachet and 17 mm open end
to remove bolt ,locknut and washer from frame
( gure 7.5.1).
7. View of 17mm nylock nut ( gure 7.5.2).
Slide Motor Assembly down and out of frame.
8. Effective for chairs prior to PLS-101619
only. With the motor removed from the chair, use
a 3mm or 1/8" pin punch to drive out the spring pin
( gure 7.5.3).
9. When re-assembling be sure the holes for the
spring pin are aligned and drive in the spring pin
with a hammer. Reverse steps 1-7 to complete
re-assembly.
Removal Procedures (cont.)
fig. 7.5.1
fig. 7.5.2
fig. 7.5.3